时间:2011-08-11 18:26来源:蓝天飞行翻译 作者:航空 点击:次
主热交换器 primary heat exchanger 次热交换器 secondary heat exchanger 温度指示器 temperature indicator 压差指示器 differential press indicator 控制继电器 control relay 人工超控继电器 manual override relay 区域温度灯 ZONE TEMP light 温度探头灯 TEM probe light 自动温度控制 auto temperature control 设备冷却排气关断/供气灯 EQUIP cooling exhaust off/supply light 引气温度指示 bleed air TEMP indication 引气温度选择器 bleed air temperature selector 左/右组件位 pack L /R 客舱前/后区位 FWD /AFT ZONE cabin 前/后供气管路位 FWD/ AFT supply duct 驾驶舱供气管路位 CONT CAB supply duct 1) 驾驶舱供气管道引气温度指示CONT CABIN supply duct air temperature indication 2) 前舱/后舱/驾驶舱温度自动控制FWD/AFT/CONT CAB temperature auto control 3) 无气流从脚部/风挡出气口流出。No airflow from foot /windshield outlet 4) 人工方式下后排气活门不工作。Aft outflow valve does not operate in manual mode 5) 自动失效和备用灯亮,当增压方式选择器电门在备用位时,自动失效灯灭。AUTO FAIL light and ALTN light come on, AUTO FAIL light goes off when pressurization mode selector switch is at the ALTN position 6) 不能保持恰当的机舱压力。Can not keep the correct cabin pressure 7) 航后检查右冲压进气口折流门后部的封严板有两处破损。Two disrepairs of the R/H ram air inlet deflector panel were found broken during AF check. 8) 右 PACK灯再现时亮,警告信号抑制后熄灭 Right PACK light comes on during recalling and goes off after warning signal inhibited. 9) 过站检查再现故障时左组件PACK灯点亮,按压主警告可以熄灭。The L/H PACK light comes on when recalling the fault in TR, but it could extinguish by pressing master caution light. 10) 航前检查飞机,驾驶舱温度很高,温度调节器均放全冷位,管道温度不下降, 驾驶舱温度保持不变。The temperature is still high after putting the temperature selectors to fully cold position, and the temperature of the duct is also too high in PF. 11) 航后检查发现右冲压进气道折流门后部气流挡板断裂.the rear deflector panel of the R/H ram air inlet is broken during AF check 12) 航后机组反映,右组件“PACK"灯按后再现亮。AF, the crew reported that the R/H “PACK" light came on after recalling it. 13) 巡航时左PACK故障灯亮无法复位.The L/H PACK light comes on on cruise and can not be reset. 14) 左侧空调组件灯再现时亮,复位后灯灭,空中飞行观察增压正常.In the air the left PACK light is on and then off after reset. The pressurization and the pressure are normal in flight. 15) 再现检查时左PACK灯亮,清除主警告后PACK灯灭.The left PACK came on after RECALL and it went off after pressing the MASTER CAUTION button. 16) 拆除并安装前外流活门 Remove and install forward outflow valve 17) 拆除并安装左发预冷器控制活门 Remove and install the precooler control valve of L/H ENG 18) 更换再循环风扇气滤 Replace recirculation fan filter 19) 拆除并安装左空调组件活门 Remove and install L/H pack valve 20) 拆除并安装35f控制器 Remove and install 35f controller 21) 更换左空调组件ACM的滑油 Replace the left pack ACM oil 22) 检查右空调聚水袋 Check/inspect right pack water coalesce bag 23) 35f控制活门的拆装 Remove and install the 35f control valve 24) 主热交换器的拆装 Remove and install primary heat exchanger 25) 对组件/区域温度控制器进行自检 Pack/zone temperature controllers BITE test 26) 更换再循环风扇滤子 Replace recirculation fan filter |