(a)
Oxygen (O2) bottles and liquid fire extinguishers. Inspections, hydrostatic tests, and life limits of pressure vessels manufactured under a DOT specification are accomplished as set forth in 49 CFR Part 180.209, as amended.
(b)
Fire extinguishers. Inspections, hydrostatic tests, and life limits of portable fire extinguishers are accomplished as set forth in 46 CFR Sections 71.25 and 162.028, as amended.
(c)
Military-manufactured. Pressure vessels manufactured under a MIL-SPEC are maintained in accordance with the applicable military specifications.
(d)
Foreign-manufactured. Foreign-manufactured pressure cylinders are maintained in accordance with the applicable foreign manufacturer’s specifications.
(e)
Other. Pressure cylinders not manufactured under DOT, foreign, or U.S. MIL-SPECS are maintained in accordance with the applicable aircraft manufacturer’s specifications.
Emergency Equipment
Emergency Equipment Items Maintenance Document Limitations and Provisions
Fire Extinguisher See label
Print Date: 08/28/2008 D104-1 CERTIFICATE NO.: W9WA460Y Air West, Inc.
U.S. Department
of Transportation Federal Aviation Operations Specifications Administration
1.
The Certificate Holder applies for the Operations in this paragraph.
2.
Support information reference:
3.
These Operations Specifications are approved by direction of the Administrator.
DIGITALLY FAA SIGNED 9/14/04 12:05:16 PM
Bean, George W.
Principal Maintenance Inspector
4.
Date Approval is effective: 09/14/2004 Amendment Number: 2
5.
I hereby accept and receive the Operations Specifications in this paragraph.
DIGITALLY INDUSTRY SIGNED 9/14/04 11:51:32 AM
Chevaleau, Robert M.
|