时间:2017-08-16 10:51来源:蓝天飞行翻译公司 作者:民航翻译 点击:次
21-31-05 (-300QC/F, -400F) (STC’s ST01566LA, SA2969SO and SA2970SO only) 21-31-05-01 STC SA2970SO 21-32 Pack Temperature Control System(s) (Electronic Pack/Zone Controller) (-400/-800/-900/-900ER) 21-33 Pack Temperature Control Valves (-400/-800/-900/-900ER) 21-33A Pack Temperature Control Valve Inoperative Closed 21-33B Pack Temperature Control Valve Deactivated Closed 21-33C Associated Pack Not Used 21-34 Standby Pack Temperature Control Valves (-400/-800/-900/-900ER) 21-34A Pack Temperature Control Valve(s) Operate Normally 21-34B Associated Pack Not Used 21-35 Trim Air Pressure Regulating and Shutoff Valve 21-35-01 -400/-800 21-35-02 -900/-900ER 21-36 Trim Air Modulating Valves 21-36-01 -400/-800 21-36-01A Inoperative Closed 21-36-01B Inoperative In Any Position 21-36-02 -900/-900ER 21-36-02A Inoperative Closed 21-36-02B Inoperative In Any Position 21-37 Outflow Valve Heater Gasket (-100/-200/-300/-400/-500) 21-38 Outflow Valve Position Indicator 21-39 Trim Air Check Valves 21-39-01 (-400/-800/-900/-900ER) 21-40 Equipment Cooling Automatic Flow Control Valve/Overboard Exhaust Valve 21-40-01 Analog Control System (-100/-200/-300/-400/ -500) 21-40-01A Inoperative Open 21-40-01B Inoperative Closed 21-40-02 Digital Control System 21-40-02-01 -300/-400/-500 21-40-02-01A Inoperative Open 21-40-02-01B Inoperative Closed 21-40-02-02 -600/-700/-800 (prior to incorporation of Boeing Service Bulletins 737-26-1121 and 737-26-1122, and either 737-21-1135 or 737-21-1163, or their production equivalents) 21-40-02-03 -600/-700/-800 (upon incorporation of Boeing Service Bulletins 737-26-1121 and 737-26-1122, and either 737-21-1135 or 737-21-1163, or their production equivalents) 21-40-02-04 -900/-900ER 21-40-02-05 -600/-700/-800/-900/-900ER 21-41 Door Area Heater Systems 21-41-01 Main Deck Cargo Door Heating Blankets/System (737C and -700C) 21-41-02 Entry Door Area and Overwing Emergency Exit Hatch Area Heater Systems (-600/-700/-800/-900/-900ER) 21-41-03 Main Cargo Door Heater System (STC ST01566LA) 21-41-04 Mid-Exit Door Area Heater System (-900ER) 21-42 Equipment Cooling Low Flow Detector Systems (-600/-700/-800/-900/-900ER) 21-43 Equipment Cooling Air Filter (-600/-700/-800/-900/-900ER) 21-44 Fan Bypass Check Valves (-600/-700/-800/-900/-900ER) 21-44A Airport OAT Below 80 Deg F (27 Deg C) 21-44B Associated Pack Inoperative 21-44C One Inoperative, Opposite Pack Operates Normally 21-45 Air Distribution Riser Shutoff Valves (-700C) 21-45-01 Passenger Configuration 21-45-02 Passenger and Cargo Configurations 21-45-02-01 Right Riser SOV 21-45-02-02 Left Riser SOV 21-46 Air Heater Supernumerary Compartment STC ST01566LA (-300RB) and ST01961SE 21-47 Humidification System (-800EF STC ST02000NY) 21-48 Zonal Drying System (-800EF STC ST02000NY) |