时间:2017-08-16 10:51来源:蓝天飞行翻译公司 作者:民航翻译 点击:次
21-19-02-02 -400/-800 21-19-02-02A Trim Air PRSOV Remains CLOSED 21-19-02-02B Trim Air Modulating Valve Deactivated CLOSED 21-19-02-03 -900/-900ER 21-19-02-03A Trim Air PRSOV Remains CLOSED 21-19-02-03B Trim Air Modulating Valve Deactivated CLOSED 21-20 MOVED (Cabin Temperature Indicator) 21-21 Flight Deck Temperature Control Systems 21-21-01 Automatic / Manual Controls (-100/-200/-300/-500/-600/-700) 21-21-01A One System Inoperative 21-21-01B Both Systems Inoperative, Left Pack Is Not Used 21-21-02 Primary / Back-up Modes 21-21-02-01 (-400/-800/-900/-900ER) 21-21-02-02 (-400/-800) 21-21-02-02A Trim Air PRSOV Remains CLOSED 21-21-02-02B Trim Air Modulating Valve Deactivated CLOSED 21-21-02-03 (-900/-900ER) 21-21-02-03A Trim Air PRSOV Remains CLOSED 21-21-02-03B Trim Air Modulating Valve Deactivated CLOSED 21-22 Forward Outflow Valve (-100/-200/-300/-400/-500, Including STC’s SA2969SO, ST01566LA, and ST01961SE) 21-22A Valve Inoperative Closed 21-22B Valve Inoperative Open, Both Packs Operate Normally 21-22C Valve Inoperative Open, One Pack Operates Normally 21-23 FORWARD OUTFLOW CLOSED Indicating Light (-100/-200) 21-24 Gasper Fan (-100/-200/-300/-500/-600/-700) 21-25 Water Separator Anti-Icing Systems (-100/-200/-300/-500/-600/-700) 21-26 Ground Preconditioned Air Connection Check Valve 21-26-01 Analog Control System (-100/-200/-300/-400/ -500) 21-26-02 Digital Control System 21-26-02-01 -300/-400/-500 21-26-02-02 (-600/-700/-800 prior to incorporation of Boeing Service Bulletins 737-26-1121 and 737-26-1122, and either 737-21-1135 or 737-21-1163, or their production equivalents) 21-26-02-03 (-600/-700/-800 upon incorporation of Boeing Service Bulletins 737-26-1121 and 737-26-1122, and either 737-21-1135 or 737-21-1163, or their production equivalents) 21-26-02-04 -900/-900ER 21-27 Electrical/Electronic Equipment Cooling Blowers 21-27-01 Non-EFIS (-100/-200/-300/-400/-500) 21-27-02 EFIS (-300/-400/-500) 21-27-02-01 Supply Fans 21-27-02-02 Exhaust Fans 21-27-03 CDS (-600/-700/-800/-900/-900ER) 21-28 Equipment Cooling Check Valve (-100/-200) 21-29 Air Cleaner Purge Valves (-100/-200/-300) 21-30 Control Cabin Augmentation Fan (-200) 21-30A Fan Wind-milling OAT at or below 120 deg F (49 deg C) 21-30B Fan Wind-milling OAT at or below 115 deg F (46 deg C) 21-30C Fan seized OAT at or below 100 deg F (38 deg C) 21-31 Recirculation Fan(s) 21-31-01 -300/-500 21-31-02 -400 and Pemco -400 COMBI 21-31-02A One Recirc Fan Inoperative 21-31-02B Both Recirc Fans Inoperative 21-31-03 -600/-700 21-31-04 -800/-900/-900ER 21-31-04A Left Recirc Fan Inoperative 21-31-04B Right Recirc Fan Inoperative 21-31-04C Both Fans Inoperative 21-31-04-01 -800EF STC ST02000NY 21-31-04-02 -900/-900ER With Greenpoint Technologies, Inc. Interior Installation G12111000-101 STC ST11040SE |