时间:2014-02-25 11:46来源:蓝天飞行翻译 作者:航空 点击:次
GO-AROUND WITH ONE ENGINE INOPERATIVE (FINAL APPROACH WITH SF 3) 3-120 - HYDRAULIC SYSTEM Loss of #1 or #2 hydraulic system; Failure of a pump of #1 hydraulic system MASTER + GONG with HYDR #1 PUMP 1+3 message in Crew Alerting System. MASTER + GONG with HYDR #1 PUMP 1 or HYDR #1 PUMP 3 message in Crew AlertingSystem. MASTER + GONG with HYDR #2 PUMP 2 message in Crew Alerting System. Hydraulic system low level MASTER + GONG with HYDRAULIC LOW LEVEL 1 message in Crew Alerting System. MASTER + GONG with HYDRAULIC LOW LEVEL 2 message in Crew Alerting System. Stand-by pump malfunction MASTER + GONG with STBY PUMP PERMANENT message in Crew Alerting System. MASTER + GONG with STBY PUMP ON C#1 message in Crew Alerting System. 3-130 - FLIGHT CONTROLS Landing with stabilizer inoperative or elevator inoperative LANDING WITH STABILIZER INOPERATIVE LANDING WITH ELEVATOR INOPERATIVE Arthur unit inoperative |